SEFRAM 4451 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Vodní pumpy SEFRAM 4451. SEFRAM 4451 Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - SEFRAM 4451

SEFRAM 4451 50 MHz PROGRAMMABLE PULSE GENERATOR OPERATING MANUAL

Strany 2

Operating Manual SEFRAM 4451 M4451 A00 10 Range - 10ns to (Period - 10ns off time). Resolution - Up to 6 digits, limited to 100 ps. A

Strany 3

Operating Manual SEFRAM 4451 M4451 A00 11100ns; 50ns-1.0us; 500ns-10us; 5.0us-100us; 50us-1.0ms; 500us-10ms, 5 ms – 100 ms. Resolution -

Strany 4

Operating Manual SEFRAM 4451 M4451 A00 12 GPIB PROGRAMMING Internal - IEEE-488.2 and SCPI compatible. Address - 0-30 front panel se

Strany 5 - Safety Summary

Operating Manual SEFRAM 4451 M4451 A00 13

Strany 6

Operating Manual SEFRAM 4451 M4451 A00 14 Section 2 Installation 2.1 Introduction This section contains installation infor

Strany 7

Operating Manual SEFRAM 4451 M4451 A00 15 2.6 Grounding Requirements To minimize shock hazard, the instrument chassis and cabinet must be

Strany 8 - General Information

Operating Manual SEFRAM 4451 M4451 A00 16 2.7.2 Impedance Matching A mismatch, or different impedance in a transmission line, generates a

Strany 9

Operating Manual SEFRAM 4451 M4451 A00 17 For example: to match a 50Ω system to a 125Ω system, Z1 equals 50Ω and Z2 equals 125Ω Therefore:

Strany 10 - : - ± 1% ± 25 mV

Operating Manual SEFRAM 4451 M4451 A00 18than the combined rise times of the testing system, determine the actual rise time of the device und

Strany 11

Operating Manual SEFRAM 4451 M4451 A00 19DB-9 pin Name Note Computer DB25 pin Direction 1 2 3 4 5 6 7 8 9 N/C RXD TXD N/C GND N/C RTS CRS

Strany 12

Operating Manual SEFRAM 4451 M4451 A00 2

Strany 13 - M4451 A00

Operating Manual SEFRAM 4451 M4451 A00 20

Strany 14 - Installation

Section 3 Operating Instructions 3.1 General Description This section describes the displays, controls and connectors of the SEFRAM 4451 Pulse

Strany 15

Operating Manual SEFRAM 4451 M4451 A00 22output, parameter or mode displayed selected. 3.3 Front Panel Controls The front-panel controls

Strany 16 - RZZZ1221=−()

Operating Manual SEFRAM 4451 M4451 A00 233.6 MENU Keys These keys select the main menus for displaying or changing a parameter, function o

Strany 17 - R1 125 125 50 96 8=−=()

Operating Manual SEFRAM 4451 M4451 A00 24 F3: DELAY - This parameter is used in two instances. The first is to set the delay of the puls

Strany 18

Operating Manual SEFRAM 4451 M4451 A00 25 OUTPUT Menu F1: HILVL - Selects the pulse high level voltage. F2: LOLVL - Selects

Strany 19 - 2.10 RS-232 Configuration

Operating Manual SEFRAM 4451 M4451 A00 26 3.6.3 PULSE Menu PULSE Menu F1: RISE - Selects the pulse Rise

Strany 20

Operating Manual SEFRAM 4451 M4451 A00 27 3.6.4 MODE Menu Selects the output mode: CONT (Continuous), TRIG (Triggered), GATE (Gated), BRS

Strany 21 - Operating Instructions

Operating Manual SEFRAM 4451 M4451 A00 28 Trigger Menu F1: MAN - Selects manual as the trigger source. Pressing the M

Strany 22

Operating Manual SEFRAM 4451 M4451 A00 29 SETUPS Menu F1: RECALL

Strany 23

Operating Manual SEFRAM 4451 M4451 A00 3 INDEX Page SAFETY SUMMARY Section 1 General Information 5 1.1 Int

Strany 24

Operating Manual SEFRAM 4451 M4451 A00 30 GPIB Menu F2: RS232 -Selects the RS232 remote control mo

Strany 25

Operating Manual SEFRAM 4451 M4451 A00 31When the pulse generator finishes the diagnostic self-test routine, it enters the local state (LOGS)

Strany 26

Operating Manual SEFRAM 4451 M4451 A00 32 Error messages for SEFRAM 4451 Message Text Cause Setting conflict Can&apo

Strany 27

Operating Manual SEFRAM 4451 M4451 A00 33 SETTLING TIME is the interval required for the pulse level to enter and remain in the specified le

Strany 28

Operating Manual SEFRAM 4451 M4451 A00 34 (0.99 * Trig Rate) must be > (Period * Burst Count)

Strany 29

Operating Manual SEFRAM 4451 M4451 A00 35

Strany 30

Operating Manual SEFRAM 4451 M4451 A00 36

Strany 31

Section 4 Programming 4.1 OVERVIEW This section provides detailed information on programming the SEFRAM 4451 via the IEEE 488 bus (GPIB - General Pu

Strany 32

Operating Manual SEFRAM 4451 M4451 A00 36Setting the device to address 31 puts it in the 'off-bus' state. In this state it will not

Strany 33

Operating Manual SEFRAM 4451 M4451 A00 37 4.9.1 General Command Structure The device commands are generally defined by the SCPI standard, w

Strany 34

Operating Manual SEFRAM 4451 M4451 A00 4Section 5 Performance Check Procedure 66 5.1 Introduction 67 5.2 Test Equipment 67 5.3 E

Strany 35

Operating Manual SEFRAM 4451 M4451 A00 38The Program Data represent the values of the parameters being set, for example, the '1US'

Strany 36

Operating Manual SEFRAM 4451 M4451 A00 39 SOURCE:FREQUENCY 3KHZ;:OUTPUT:STATE ON Common Commands may be inserted in the Program Message wi

Strany 37 - Programming

Operating Manual SEFRAM 4451 M4451 A00 40Bit 3: Device-Specific Error (DDE). This bit is set to indicate that a device operation did not exe

Strany 38 - 4.9 COMMAND SYNTAX

Operating Manual SEFRAM 4451 M4451 A00 41 4.10.5.1 Command Errors A command error is in the range -199 to -100, and indicates that a syntax

Strany 39

Operating Manual SEFRAM 4451 M4451 A00 42A query error indicates that the output queue control has detected a problem. This could occur if ei

Strany 40

Operating Manual SEFRAM 4451 M4451 A00 43 4.11.3 Synchronization Commands 4.11.3.1 *OPC - Operation Complete Command The operation complet

Strany 41

Operating Manual SEFRAM 4451 M4451 A00 44COMMAND TYPE: Common Command or Query Syntax: *ESR? Response: <NR1> 4.11.4.4 *PSC - Power-On

Strany 42

Operating Manual SEFRAM 4451 M4451 A00 45Syntax: *TRG 4.11.6 Stored Settings Commands 4.11.6.1 *RCL - Recall Instrument State This comman

Strany 43

Operating Manual SEFRAM 4451 M4451 A00 46 :DOUBle [:STATe] <Boolean> :DELay <NRf> :TRANsition [:LEADing] <NRf>

Strany 44

Operating Manual SEFRAM 4451 M4451 A00 47This command is used to set the low level of the pulse. COMMAND TYPE: Setting or Query SETTING Synt

Strany 45

Operating Manual SEFRAM 4451 M4451 A00 5 Safety Summary The following safety precautions apply to both operating and maintenance personnel an

Strany 46

Operating Manual SEFRAM 4451 M4451 A00 48QUERY Syntax: [:SOURce]:VOLTage[:LEVel][:IMMediate]:PLOW? Examples: :VOLT:PLOW? Response: NRf 4.12.1

Strany 47

Operating Manual SEFRAM 4451 M4451 A00 49QUERY Syntax: [:SOURce]:VOLTage:LIMit:LOW? Examples: :VOLT:LIM:LOW? Response: NRf CONSIDERATIONS:

Strany 48

Operating Manual SEFRAM 4451 M4451 A00 504.12.1.11 Pulse Delay This command is used to set the delay from the trigger signal to the start of

Strany 49

Operating Manual SEFRAM 4451 M4451 A00 51SETTING Syntax: [:SOURce]:PULSe:HOLD<ws><option> Arguments: Type: Character Options: WID

Strany 50

Operating Manual SEFRAM 4451 M4451 A00 52This command is used to set the delay of the second pulse, from the time of the trigger, in the doub

Strany 51

Operating Manual SEFRAM 4451 M4451 A00 534.12.1.18 Trailing Edge Time This command is used to set the value of the trailing edge time. If th

Strany 52

Operating Manual SEFRAM 4451 M4451 A00 54This command is used to control the polarity of the pulse, which may be normal or complemented. The

Strany 53

Operating Manual SEFRAM 4451 M4451 A00 55:BURSt <NRf> :SOURce <MANual> | INTernal | EXTernal | BUS :TIMer <NRf> :LEVel <

Strany 54

Operating Manual SEFRAM 4451 M4451 A00 56QUERY Syntax: :TRIGger:BURSt? Response: NRf Examples: :TRIG:BURSt? 4.12.3.4 Internal Trigger Rate S

Strany 55

Operating Manual SEFRAM 4451 M4451 A00 57Syntax: :TRIGger:SLOPe? Examples: :TRIG:SLOP? Response: POS | NEG 4.12.4 Status Subsystem This s

Strany 56

Operating Manual SEFRAM 4451 M4451 A00 6 WARNING: To avoid electrical shock hazard, disconnect power cord before removing covers. Refer ser

Strany 57

Operating Manual SEFRAM 4451 M4451 A00 58Communication with the instrument can be resumed only by setting the address to a suitable value fro

Strany 58

Operating Manual SEFRAM 4451 M4451 A00 59COMMAND TYPE: Setting or Query SETTING Syntax: :SYSTem:POBuffer<ws><buffer> Arguments:

Strany 59

Operating Manual SEFRAM 4451 M4451 A00 60 4.14 SCPI COMMAND TREE 4.14.1 Root Node Root[:SOURce] :OUTPut :TRIGger :STATus :SYSTem 4.14.2

Strany 60

Operating Manual SEFRAM 4451 M4451 A00 61 4.14.4 TRIGger Subsystem :TRIGger:SLOPe POS | NEG :LEVel <NRF> :TIMer <NRf>

Strany 61

Operating Manual SEFRAM 4451 M4451 A00 62:SYSTem :COMMunicate :GPIB :ADDRess <NRf> :ERRor? :SECurity [:STATe]? ON | OFF:POB

Strany 62 - 4.14 SCPI COMMAND TREE

Operating Manual SEFRAM 4451 M4451 A00 63 4.15 RS-232 Programming

Strany 63

Operating Manual SEFRAM 4451 M4451 A00 64 4.15.1 General The INSTALLATION section of this manual describes the RS-232-C connection for the i

Strany 64

Operating Manual SEFRAM 4451 M4451 A00 65

Strany 65

Operating Manual SEFRAM 4451 M4451 A00 66 Section 5 Performance Check Procedure 5.1 Introduction This section contains the test proc

Strany 66 - 4.15.2 RS-232-C Operation

Operating Manual SEFRAM 4451 M4451 A00 68The following tests are intended to verify that the SEFRAM 4451 operates properly and meets its spec

Strany 67

Operating Manual SEFRAM 4451 M4451 A00 7

Strany 68 - Section 5

Operating Manual SEFRAM 4451 M4451 A00 69 input with a 50Ω termination. Select leading and trailing times. CHECK - The Rise and

Strany 69

Operating Manual SEFRAM 4451 M4451 A00 70 To contac us : SEFRAM Instruments et Systèmes 32, rue E. MARTEL BP55 F 42009 – SAINT-ETIENNE ced

Strany 70

Operating Manual SEFRAM 4451 M4451 A00 71DECLARATION OF CE CONFORMITY according to EEC directives and NF EN 45014 norm DECLARATION DE CONFORM

Strany 71 - (0,15€TTC/mn)

Section 1 General Information 1.1 Introduction This manual contains information required to operate, program, check and maintain the

Strany 72 - DECLARATION OF CE CONFORMITY

Operating Manual SEFRAM 4451 M4451 A00 9 1.4 SPECIFICATIONS The following specifications describe the instrument performance after a 20 mi